Fanuc 0i-M NCnet 7.0 settings

Page 1 sur 3Lecteur de document UniversityLib

Fanuc 0i-M NCnet 7.0 settings

Industrial CNC Machine Configuration · notes

Voir tous les documents en génie mécanique

Fanuc 0i- M

NCnet 7.0 settings

Set these parameters on the machine

0000

0020

0100

0101

0102

0103

= 00000010

= 0

= 00100000

= 10000001

= 0

= 11

Set the setting data as follows:

TV CHECK

Punch code

I/O Channel

= 0

= 1

= 0

To set the controller in the Drip-feed mode

Select AUTO (DNC) mode on machine

Press Cycle start

Parameters for the various baud rates

For baud rates other than 9600 set 0103 as follows:

Baud rate Parameter

150

200

300

600

1200

2400

4800

9600

19200

4

5

6

7

8

9

10

11

12

Set the following parameters on the PC

Publicité

Machine details

Machine name

Control system

Machine ID

Communication Channel

Port Number

Folder for PC to Machine transfer

Folder for Machine to PC transfer

Baud rate

Data bits

Parity

Stop bits

Handshake

MCH-1

Fanuc

01

Serial Port

Any free COM port

Transmit directory

Receive directory

9600

7

Even

2

Hardware

Page 1 of 3

General settings

Ignore this. Leave all data as it is.

Transmit settings

Wait period at start of transmission

Wait period after transmitting program

Size of transmit packet

Delay period after each packet

Wait for XON before transmitting program

Transmit comments?

Comment start character

Comment end character

Translation mode for CR

Translation mode for LF

Acknowledgement and error (Mode of transmission)

ACK/ERR Message start text

ACK/ERR Message start text

Filter Null Character

10.00

5.0

0

0

Publicité

No

Yes

(

)

Transmit as CR

Transmit as LF

Transmit descriptive message

%

O1234

M30

%

Yes

NC Program settings

Program start string

Program end string

Characters to transmit at start

Characters to transmit at start

Receive settings

0

0

Number of Characters

Number of Characters

0

0

Wait period before receiving program

Wait period after receiving program

Transmit XON before transmitting program

Auto compare and save

Acknowledgements and errors

Translation mode for CR

Translation mode for LF

Ignore control characters other than CR-LF

Save Program between Start Characters and End Characters

Start Program reception after these characters are received

End Program reception after these characters are received

To set the PC in the Drip-feed mode

Set Handshake to = Software

Set Drip feed = ON

45.0

5.0

No

Yes

Transmit descriptive messages

Ignore

Save as CRLF

Yes

No

Publicité

Page 2 of 3

Cable connections

If the PC has 9 pin connector

Null modem

Full Handshake

PC

9 pin

CNC

25 pin

PC

9 pin

CNC

25 pin

1

2

3

4

5

6

7

8

8

2

3

20

7

6

4

5

1

2

3

4

5

6

7

8

8

2

3

6

7

20

5

4

If the PC has 25 pin connector

Null modem

Publicité

Full Handshake

PC

25 pin

CNC

25 pin

PC

25 pin

CNC

25 pin

8

2

3

20

7

6

4

5

8

3

2

20

7

6

4

5

8

2

3

20

7

6

4

5

8

3

2

6

7

20

5

4

Page 3 of 3