Fanuc 0i- M
NCnet 7.0 settings
Set these parameters on the machine
0000
0020
0100
0101
0102
0103
= 00000010
= 0
= 00100000
= 10000001
= 0
= 11
Set the setting data as follows:
TV CHECK
Punch code
I/O Channel
= 0
= 1
= 0
To set the controller in the Drip-feed mode
Select AUTO (DNC) mode on machine
Press Cycle start
Parameters for the various baud rates
For baud rates other than 9600 set 0103 as follows:
Baud rate Parameter
150
200
300
600
1200
2400
4800
9600
19200
4
5
6
7
8
9
10
11
12
Set the following parameters on the PC
Advertisement
Machine details
Machine name
Control system
Machine ID
Communication Channel
Port Number
Folder for PC to Machine transfer
Folder for Machine to PC transfer
Baud rate
Data bits
Parity
Stop bits
Handshake
MCH-1
Fanuc
01
Serial Port
Any free COM port
Transmit directory
Receive directory
9600
7
Even
2
Hardware
Page 1 of 3
General settings
Ignore this. Leave all data as it is.
Transmit settings
Wait period at start of transmission
Wait period after transmitting program
Size of transmit packet
Delay period after each packet
Wait for XON before transmitting program
Transmit comments?
Comment start character
Comment end character
Translation mode for CR
Translation mode for LF
Acknowledgement and error (Mode of transmission)
ACK/ERR Message start text
ACK/ERR Message start text
Filter Null Character
10.00
5.0
0
0
Advertisement
No
Yes
(
)
Transmit as CR
Transmit as LF
Transmit descriptive message
%
O1234
M30
%
Yes
NC Program settings
Program start string
Program end string
Characters to transmit at start
Characters to transmit at start
Receive settings
0
0
Number of Characters
Number of Characters
0
0
Wait period before receiving program
Wait period after receiving program
Transmit XON before transmitting program
Auto compare and save
Acknowledgements and errors
Translation mode for CR
Translation mode for LF
Ignore control characters other than CR-LF
Save Program between Start Characters and End Characters
Start Program reception after these characters are received
End Program reception after these characters are received
To set the PC in the Drip-feed mode
Set Handshake to = Software
Set Drip feed = ON
45.0
5.0
No
Yes
Transmit descriptive messages
Ignore
Save as CRLF
Yes
No
Advertisement
Page 2 of 3
Cable connections
If the PC has 9 pin connector
Null modem
Full Handshake
PC
9 pin
CNC
25 pin
PC
9 pin
CNC
25 pin
1
2
3
4
5
6
7
8
8
2
3
20
7
6
4
5
1
2
3
4
5
6
7
8
8
2
3
6
7
20
5
4
If the PC has 25 pin connector
Null modem
Advertisement
Full Handshake
PC
25 pin
CNC
25 pin
PC
25 pin
CNC
25 pin
8
2
3
20
7
6
4
5
8
3
2
20
7
6
4
5
8
2
3
20
7
6
4
5
8
3
2
6
7
20
5
4
Page 3 of 3